Parameter
功率◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
◆ Three phase inverter built-in mppt or pwm charge controller.
Specification | |||||
Model HDSX-T | 4KVA | 6KVA | 7KVA | 8KVA | |
Rated Power | 3.2KW | 4.8KW | 5.6KW | 6.4KW | |
Peak Power(20ms) | 9.6KW | 14.4KW | 16.8KW | 19.2KW | |
Starter Motor | 3HP | 4HP | 4HP | 4HP | |
Battery Voltage | 48/96/192VDC | ||||
Size(L*W*Hmm) | 565*300*775 | ||||
Packing Size(L*W*Hmm) | 625*360*895 | ||||
N.W.(kg) | 58 | 73 | 75 | 80 | |
G.W.(kg)(Carton Packing) | 71 | 86 | 88 | 93 | |
Installation Method | Tower | ||||
Parameter | |||||
Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) | |||
AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||
AC Input Frequency Range | 45Hz-65Hz | ||||
Max AC charging current | 20A/10A/5A | 20A/10A/5A | 20A/10A/5A | 25A/15A/10A | |
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||
Phase | 3/N/PE | ||||
Output | Efficiency(Battery Mode) | ≥85% | |||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | ||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||
Output waveform distortion | Linear load≤3% | ||||
Efficiency(AC Mode) | >99% | ||||
Output Voltage(AC Mode) | Conforming to AC input | ||||
Output Frequency(AC Mode) | Conforming to AC input | ||||
No load loss(Battery Mode) | ≤1% rated power | ||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||
No load loss(Energy saving Mode) | ≤10W | ||||
Phase | 3/N/PE | ||||
Battery type (Optional) | U0: Gel U.S.A | Charge Voltage:14V;Float Voltage:13.7V(Single battery voltage) | |||
U1: A.G.M.1 | Charge Voltage:14.1V;Float Voltage:13.4V(Single battery voltage) | ||||
U2: A.G.M.2 | Charge Voltage:14.6V;Float Voltage:13.7V(Single battery voltage) | ||||
U3: Sealed lead Acid | Charge Voltage:14.4V;Float Voltage:13.6V(Single battery voltage) | ||||
U4: Gel European | Charge Voltage:14.4V;Float Voltage:13.8V(Single battery voltage) | ||||
U5: Open lead Acid | Charge Voltage:14.8V;Float Voltage:13.5V(Single battery voltage) | ||||
U6: Calcuim(open) | Charge Voltage:15.1V;Float Voltage:13.6V(Single battery voltage) | ||||
U7: Sulphation cycle | 15.5V for 4hrs | ||||
customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements. | ||||
Protection | Battery undervoltage alarm | 11V(Single battery voltage) | |||
Battery undervoltage protection | 10.5V(Single battery voltage) | ||||
Battery overvoltage alarm | 15V(Single battery voltage) | ||||
Battery overvoltage protection | 17V(Single battery voltage) | ||||
Battery overvoltage recovery voltage | 14.5V(Single battery voltage) | ||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||
Output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||
Temperature protection | >90°C(Shut down output) | ||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||
Inside Solar controller | Charging Mode | MPPT or PWM | |||
Charging current | 48V System:10A,20A,30A,40A,50A,60A; 96V/192V System:50A,100A,150A,200A | ||||
PV Input Voltage Range | 48V System:60V-88V;96V System:120V-176V;192V System:240V-352V | ||||
Max PV Input Voltage(At 25℃) | 48V System:100V;96V System:200V;192V System:400V | ||||
PV Array Maximum Power | 48V System:560W,1120W,1680W,2240W,2800W,3360W; 96V System:5.6KW,11.2KW,8.4KW*2,11.2KW*2 192V System:11.2KW,22.4KW,16.8KW*2,22.4KW*2 | ||||
Standby loss | ≤3W | ||||
Maximum conversion efficiency | >95% | ||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||
Transfer Time | ≤4ms | ||||
Display | LCD | ||||
Thermal method | Cooling fan in intelligent control | ||||
Communication | RS232/RS485/APP/SNMP/GSM (Optional) | ||||
Environment | Operating temperature | -10℃~40℃ | |||
Storage temperature | -15℃~60℃ | ||||
Noise | 2000m(More than derating) | ||||
Elevation | ≤65dB | ||||
Humidity | 0%~95% ,No condensation | ||||
Warranty | 3 years | ||||
Note: All specifications are subject to change without prior notice |
solar inverter
HDSX-T Three phase hybrid inverter installation case
Product model:
HDSX-T series hybrid inverter 4KVA/6KVA/7KVA/8KVA DC48V/96V/192V to AC380V/400V, with 10A-200A MPPT/PWM charge controller
Certificate::
CE、TLC、IEC
Application:
Xinun hybrid inverter for single three phase motors can be used in air conditioner, refrigerator, water pump, bench drill and other electrical appliances with motors whose total power not exceeding 4kva, 6kva, 7kva or 8kva.
◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
◆ Three phase inverter built-in mppt or pwm charge controller.
HDSX-T Three phase inverter installation case
◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
◆ Three phase inverter built-in mppt or pwm charge controller.
HDSX-T Three phase inverter installation case
$1
In Stock
已选1
Buy Quantity