Parameter
功率◇ Pure sine wave output.
◆ Wide LCD screen, clear and accurate display of icon data.
◇ AC charge current 0-45A adjustable.
◆ Unbalanced loading 100% design,3 times peak power.
◇ Set up different working modes according to the use requirements of variables.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
◆ Built-in mppt or pwm solar charge controller.
Specification | |||||
Model HDSX-T | 10KVA | 15KVA | 20KVA | 25KVA | |
Rated Power | 8KW | 12KW | 16KW | 20KW | |
Peak Power(20ms) | 24KW | 36KW | 48KW | 60KW | |
Starter Motor | 5HP | 7HP | 10HP | 10HP | |
Battery Voltage | 48/96/192VDC | 96/192/384VDC | |||
Size(L*W*Hmm) | 565*300*775 | ||||
Packing Size(L*W*Hmm) | 625*360*895 | ||||
N.W.(kg) | 99 | 110 | 145 | 164 | |
G.W.(kg)(Carton Packing) | 126 | 127 | 162 | 181 | |
Installation Method | Tower | ||||
Parameter | |||||
Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) | |||
AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||
AC Input Frequency Range | 45Hz-65Hz | ||||
Max AC charging current | 25A/15A/10A | 30A/20A/10A | 30A/20A/10A | 45A/30A/15A | |
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||
Phase | 3/N/PE | ||||
Output | Efficiency(Battery Mode) | ≥85% | |||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | ||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||
Output waveform distortion | Linear load≤3% | ||||
Efficiency(AC Mode) | >99% | ||||
Output Voltage(AC Mode) | Conforming to AC input | ||||
Output Frequency(AC Mode) | Conforming to AC input | ||||
No load loss(Battery Mode) | ≤1% rated power | ||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||
No load loss(Energy saving Mode) | ≤10W | ||||
Phase | 3/N/PE | ||||
Battery type (Optional) | U0: Gel U.S.A | Charge Voltage:14V;Float Voltage:13.7V(Single battery voltage) | |||
U1: A.G.M.1 | Charge Voltage:14.1V;Float Voltage:13.4V(Single battery voltage) | ||||
U2: A.G.M.2 | Charge Voltage:14.6V;Float Voltage:13.7V(Single battery voltage) | ||||
U3: Sealed lead Acid | Charge Voltage:14.4V;Float Voltage:13.6V(Single battery voltage) | ||||
U4: Gel European | Charge Voltage:14.4V;Float Voltage:13.8V(Single battery voltage) | ||||
U5: Open lead Acid | Charge Voltage:14.8V;Float Voltage:13.5V(Single battery voltage) | ||||
U6: Calcuim(open) | Charge Voltage:15.1V;Float Voltage:13.6V(Single battery voltage) | ||||
U7: Sulphation cycle | 15.5V for 4hrs | ||||
customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements. | ||||
Protection | Battery undervoltage alarm | 11V(Single battery voltage) | |||
Battery undervoltage protection | 10.5V(Single battery voltage) | ||||
Battery overvoltage alarm | 15V(Single battery voltage) | ||||
Battery overvoltage protection | 17V(Single battery voltage) | ||||
Battery overvoltage recovery voltage | 14.5V(Single battery voltage) | ||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||
Output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||
Temperature protection | >90°C(Shut down output) | ||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||
Inside Solar controller | Charging Mode | MPPT or PWM | |||
Charging current | 48V System:10A,20A,30A,40A,50A,60A; 96V/192V/384V System:50A,100A,150A,200A | ||||
PV Input Voltage Range | 48V System:60V-88V;96V System:120V-176V;192V System:240V-352V;384V System:480V-704V | ||||
Max PV Input Voltage(At 25℃) | 48V System:100V;96V System:200V;192V System:400V;384V System:750V | ||||
PV Array Maximum Power | 48V System:560W,1120W,1680W,2240W,2800W,3360W; 96V System:5.6KW,11.2KW,8.4KW*2,11.2KW*2 192V System:11.2KW,22.4KW,16.8KW*2,22.4KW*2;384V System:22.4KW,44.8KW,33.6KW*2,44.8KW*2 | ||||
Standby loss | ≤3W | ||||
Maximum conversion efficiency | >95% | ||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||
Transfer Time | ≤4ms | ||||
Display | LCD | ||||
Thermal method | Cooling fan in intelligent control | ||||
Communication | RS232/RS485/APP/SNMP/GSM (Optional) | ||||
Environment | Operating temperature | -10℃~40℃ | |||
Storage temperature | -15℃~60℃ | ||||
Noise | 2000m(More than derating) | ||||
Elevation | ≤65dB | ||||
Humidity | 0%~95% ,No condensation | ||||
Warranty | 3 years | ||||
Note: All specifications are subject to change without prior notice |
solar inverter
HDSX-T 3 phase hybrid inverter installation case
Product model:
HDSX-T series 3 phase hybrid solar inverter 10KVA/15KVA/20KVA/25KVA DC96V/192V/384V to AC380V/400V, with 10A-200A MPPT/PWM charge controller
Certificate::
CE、TLC、IEC
Application:
Xindun 3 phase hybrid solar inverter with mppt/pwm charge controller can be used in water pump, bench drill and other high-power industrial electric with total power not exceeding 8kw, 12kw, 16kw or 20kw.
◆ Pure sine wave output.
◇ Low dc voltage to save system cost.
◆ Wide LCD screen, clear and accurate display of icon data.
◇ AC charge current 0-45A adjustable.
◆ Unbalanced loading 100% design,3 times peak power.
◇ Set up different working modes according to the use requirements of variables.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
◆ Built-in mppt or pwm solar charge controller.
HDSX-T 3 phase hybrid inverter installation case
◆ Pure sine wave output.
◇ Low dc voltage to save system cost.
◆ Wide LCD screen, clear and accurate display of icon data.
◇ AC charge current 0-45A adjustable.
◆ Unbalanced loading 100% design,3 times peak power.
◇ Set up different working modes according to the use requirements of variables.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
◆ Built-in mppt or pwm solar charge controller.
HDSX-T 3 phase hybrid inverter installation case
$1
In Stock
已选1