Parameter
功率◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
Specification | ||||||
Model: HDSX | 30KVA | 40KVA | 50KVA | 60KVA | 80KVA | |
Rated Power | 24KW | 32KW | 40KW | 48KW | 64KW | |
Battery Voltage | 192/384VDC | 384VDC | ||||
Size(L*W*Hmm) | 715*575*1275 | |||||
Packing Size(L*W*Hmm) | 775*635*1400 | |||||
N.W.(kg) | 174 | 202 | 297 | 326 | 398 | |
G.W.(kg) (Wooden Packing) | 198 | 226 | 321 | 350 | 422 | |
Parameter | ||||||
Input | AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||
AC Input Frequency Range | 45Hz-65Hz | |||||
Phase | 3/N/PE | |||||
Output | Efficiency | ≥85% | ||||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | |||||
Output Wave(Battery Mode) | Pure Sine wave | |||||
THD | liner load≤3% | |||||
AC Output Voltage Range | Conforming to AC input | |||||
AC Output Frequency Range | Conforming to AC input | |||||
Phase | 3/N/PE | |||||
Battery | DC input voltage range | 10.5-17V DC/Single battery | ||||
Battery low voltage alarm | 11V/Single battery | |||||
Battery low voltage protection | 10.5V DC/Single battery | |||||
Battery high voltage alarm | 15V/Single battery | |||||
Battery high voltage protection | 17VDC/Single battery | |||||
Battery Type | U0: Gel U.S.A / U1: A.G.M.1 /U2: A.G.M.2 / U3: Sealed lead Acid / U4: Gel European / U5: Open lead Acid / U6: Calcuim(open) / U7: Sulphation cycle | |||||
Working Mode | Battery First/AC First/Saving Energy Mode | |||||
AC Charging current(selectable) | 0~45A | |||||
Transfer Time | ≤4ms | |||||
Display | LCD | |||||
Thermal method | Forced air cooling | |||||
Protection | Over-load / Over-discharge / Short circuit / High and low temperayure | |||||
Communication | RS232/RS485/APP/SNMP/GSM (Optional) | |||||
Environment | Temperature | -10℃~40℃ | ||||
Height | 2000m(Less load when height over) | |||||
Noise | ≤65dB | |||||
Humidity | 0%~95%(No condense) | |||||
Note:All specifications are subject to charge without prior notice |
3 phase solar inverter
HDSX 3 phase solar inverter installation case
Product model:
HDSX series 3 phase solar inverter 30KVA/40KVA/50KVA/60KVA/80KVA DC192V/384V invert to AC380Volt/400Volt
Certificate::
CE、TLC、IEC
Application: 3 phase solar inverter can be used in water pump, bench drill, high-power three-phase industrial motorand with total power not exceeding 24kw, 32kw, 40kw, 48kw or 64kw.
◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
3 phase solar inverter
HDSX 3 phase solar inverter installation case
◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
3 phase solar inverter
HDSX 3 phase solar inverter installation case
$1
In Stock
已选1