Parameter
功率◇ Pure sine wave output.
◆ Wide LCD screen, clear and accurate display of icon data.
◇ AC charge current 0-45A adjustable.
◆ Unbalanced loading 100% design,3 times peak power.
◇ Set up different working modes according to the use requirements of variables.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
Specification | |||||
Model: HDSX | 10KVA | 15KVA | 20KVA | 25KVA | |
Rated Power | 8KW | 12KW | 16KW | 20KW | |
Battery Voltage | 96/192/384VDC | ||||
Size(L*W*Hmm) | 725*365*1010 | ||||
Packing Size(L*W*Hmm) | 785*425*1135 | ||||
N.W.(kg) | 99 | 110 | 145 | 164 | |
G.W.(kg) (Wooden Packing) | 126 | 127 | 162 | 181 | |
Parameter | |||||
Input | AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||
AC Input Frequency Range | 45Hz-65Hz | ||||
Phase | 3/N/PE | ||||
Output | Efficiency | ≥85% | |||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | ||||
Output Wave(Battery Mode) | Pure Sine wave | ||||
THD | liner load≤3% | ||||
AC Output Voltage Range | Conforming to AC input | ||||
AC Output Frequency Range | Conforming to AC input | ||||
Phase | 3/N/PE | ||||
Battery | DC input voltage range | 10.5-17V DC/Single battery | |||
Battery low voltage alarm | 11V/Single battery | ||||
Battery low voltage protection | 10.5V DC/Single battery | ||||
Battery high voltage alarm | 15V/Single battery | ||||
Battery high voltage protection | 17VDC/Single battery | ||||
Battery Type | U0: Gel U.S.A / U1: A.G.M.1 /U2: A.G.M.2 / U3: Sealed lead Acid / U4: Gel European / U5: Open lead Acid / U6: Calcuim(open) / U7: Sulphation cycle | ||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||
AC Charging current(selectable) | 0~45A | ||||
Transfer Time | ≤4ms | ||||
Display | LCD | ||||
Thermal method | Forced air cooling | ||||
Protection | Over-load / Over-discharge / Short circuit / High and low temperayure | ||||
Communication | RS232/RS485/APP/SNMP/GSM (Optional) | ||||
Environment | Temperature | -10℃~40℃ | |||
Height | 2000m(Less load when height over) | ||||
Noise | ≤65dB | ||||
Humidity | 0%~95%(No condense) | ||||
Note:All specifications are subject to charge without prior notice |
DC to AC inverter 3 phase
HDSX DC to AC inverter 3 phase installation case
Product model:
HDSX series DC to AC inverter 3 phase 10KVA/15KVA/20KVA/25KVA DC96V/192V/384V invert to AC380V/400V
Certificate::
CE、TLC、IEC
Application: DC to AC inverter 3 phase can be used in water pump, bench drill and other industrial electric with total power not exceeding 8kw, 12kw, 16kw or 20kw.
◆ Pure sine wave output.
◇ Low dc voltage to save system cost.
◆ Wide LCD screen, clear and accurate display of icon data.
◇ AC charge current 0-45A adjustable.
◆ Unbalanced loading 100% design,3 times peak power.
◇ Set up different working modes according to the use requirements of variables.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
DC to AC inverter 3 phase
HDSX DC to AC inverter 3 phase installation case
◆ Pure sine wave output.
◇ Low dc voltage to save system cost.
◆ Wide LCD screen, clear and accurate display of icon data.
◇ AC charge current 0-45A adjustable.
◆ Unbalanced loading 100% design,3 times peak power.
◇ Set up different working modes according to the use requirements of variables.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
DC to AC inverter 3 phase
HDSX DC to AC inverter 3 phase installation case
$1
In Stock
已选1
Buy Quantity