Parameter
功率◇ Pure sine wave output.
◆ The LCD display shows the icon data clearly and accurately.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Set up different working modes according to the use requirements of variables.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
| Specification | ||||
| Model: HDSX | 100KVA | 125KVA | 150KVA | |
| Rated Power | 80KW | 100KW | 120KW | |
| Battery Voltage | 384VDC | |||
| Size(L*W*Hmm) | 925*760*1450 | |||
| Packing Size(L*W*Hmm) | 990*825*1590 | |||
| N.W.(kg) | 850 | 900 | 1120 | |
| G.W.(kg) (Wooden Packing) | 895 | 945 | 1165 | |
| Parameter | ||||
| Input | AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||
| AC Input Frequency Range | 45Hz-65Hz | |||
| Phase | 3/N/PE | |||
| Output | Efficiency | ≥85% | ||
| Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||
| Output Frequency(Battery Mode) | 50/60Hz ±1% | |||
| Output Wave(Battery Mode) | Pure Sine wave | |||
| THD | liner load≤3% | |||
| AC Output Voltage Range | Conforming to AC input | |||
| AC Output Frequency Range | Conforming to AC input | |||
| Phase | 3/N/PE | |||
| Battery | DC input voltage range | 10.5-17V DC/Single battery | ||
| Battery low voltage alarm | 11V/Single battery | |||
| Battery low voltage protection | 10.5V DC/Single battery | |||
| Battery high voltage alarm | 15V/Single battery | |||
| Battery high voltage protection | 17VDC/Single battery | |||
| Battery Type | U0: Gel U.S.A / U1: A.G.M.1 /U2: A.G.M.2 / U3: Sealed lead Acid / U4: Gel European / U5: Open lead Acid / U6: Calcuim(open) / U7: Sulphation cycle | |||
| Working Mode | Battery First/AC First/Saving Energy Mode | |||
| AC Charging current(selectable) | 0~45A | |||
| Transfer Time | ≤4ms | |||
| Display | LCD | |||
| Thermal method | Forced air cooling | |||
| Protection | Over-load / Over-discharge / Short circuit / High and low temperayure | |||
| Communication | RS232/RS485/APP/SNMP/GSM (Optional) | |||
| Environment | Temperature | -10℃~40℃ | ||
| Height | 2000m(Less load when height over) | |||
| Noise | ≤65dB | |||
| Humidity | 0%~95%(No condense) | |||
| Note:All specifications are subject to charge without prior notice | ||||


3 phase off grid inverter

HDSX 3 phase off grid inverter installation case
Product model:
HDSX series 3 phase off grid inverter 100KVA/125KVA/150KVA, DC384V invert to AC380V/400V(customized AC190V/200V)
Certificate::
CE、TLC、IEC
Application: 3 phase off grid inverter can be used in high-power water pump, bench drill and other three-phase industrial motorands with total power not exceeding 80kw, 100kw or 120kw.
◆ Pure sine wave output.
◇ Low dc voltage to save system cost.
◆ The LCD display shows the icon data clearly and accurately.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Set up different working modes according to the use requirements of variables.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).



3 phase off grid inverter

HDSX 3 phase off grid inverter installation case
◆ Pure sine wave output.
◇ Low dc voltage to save system cost.
◆ The LCD display shows the icon data clearly and accurately.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Set up different working modes according to the use requirements of variables.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).



3 phase off grid inverter

HDSX 3 phase off grid inverter installation case
$1
In Stock
已选1
Buy Quantity