Parameter
功率◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
◆ Built-in pwm charge controller.
| Specification | ||||||
| Model HDSX-T | 30KVA | 40KVA | 50KVA | 60KVA | 80KVA | |
| Rated Power | 24KW | 32KW | 40KW | 48KW | 64KW | |
| Peak Power(20ms) | 72KW | 96KW | 120KW | 144KW | 192KW | |
| Starter Motor | 15HP | 15HP | 20HP | 25HP | 30HP | |
| Battery Voltage | 192/384VDC | 384VDC | ||||
| Size(L*W*Hmm) | 715*575*1275 | |||||
| Packing Size(L*W*Hmm) | 775*635*1400 | |||||
| N.W.(kg) | 174 | 202 | 297 | 326 | 398 | |
| G.W.(kg)(Carton Packing) | 198 | 226 | 321 | 350 | 422 | |
| Installation Method | Tower | |||||
| Parameter | ||||||
| Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) | ||||
| AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||||
| AC Input Frequency Range | 45Hz-65Hz | |||||
| Max AC charging current | 30A/15A | 40A/20A | 45A/25A | 45A/30A | 30A | |
| AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||||
| Phase | 3/N/PE | |||||
| Output | Efficiency(Battery Mode) | ≥85% | ||||
| Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||||
| Output Frequency(Battery Mode) | 50/60Hz ±1% | |||||
| Output Wave(Battery Mode) | Pure Sine Wave | |||||
| Output waveform distortion | Linear load≤3% | |||||
| Efficiency(AC Mode) | >99% | |||||
| Output Voltage(AC Mode) | Conforming to AC input | |||||
| Output Frequency(AC Mode) | Conforming to AC input | |||||
| No load loss(Battery Mode) | ≤1% rated power | |||||
| No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | |||||
| No load loss(Energy saving Mode) | ≤10W | |||||
| Phase | 3/N/PE | |||||
| Battery type (Optional) | U0: Gel U.S.A | Charge Voltage:14V;Float Voltage:13.7V(Single battery voltage) | ||||
| U1: A.G.M.1 | Charge Voltage:14.1V;Float Voltage:13.4V(Single battery voltage) | |||||
| U2: A.G.M.2 | Charge Voltage:14.6V;Float Voltage:13.7V(Single battery voltage) | |||||
| U3: Sealed lead Acid | Charge Voltage:14.4V;Float Voltage:13.6V(Single battery voltage) | |||||
| U4: Gel European | Charge Voltage:14.4V;Float Voltage:13.8V(Single battery voltage) | |||||
| U5: Open lead Acid | Charge Voltage:14.8V;Float Voltage:13.5V(Single battery voltage) | |||||
| U6: Calcuim(open) | Charge Voltage:15.1V;Float Voltage:13.6V(Single battery voltage) | |||||
| U7: Sulphation cycle | 15.5V for 4hrs | |||||
| customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements. | |||||
| Protection | Battery undervoltage alarm | 11V(Single battery voltage) | ||||
| Battery undervoltage protection | 10.5V(Single battery voltage) | |||||
| Battery overvoltage alarm | 15V(Single battery voltage) | |||||
| Battery overvoltage protection | 17V(Single battery voltage) | |||||
| Battery overvoltage recovery voltage | 14.5V(Single battery voltage) | |||||
| Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||
| Output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||
| Temperature protection | >90°C(Shut down output) | |||||
| Alarm | A | Normal working condition, buzzer has no alarm sound | ||||
| B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||||
| C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||||
| Inside Solar controller | Charging Mode | PWM | ||||
| Charging current | 192V/384V System:50A,100A,150A,200A | |||||
| PV Input Voltage Range | 192V System:240V-352V;384V System:480V-704V | |||||
| Max PV Input Voltage(At 25℃) | 192V System:400V;384V System:750V | |||||
| PV Array Maximum Power | 192V System:11.2KW,22.4KW,16.8KW*2,22.4KW*2;384V System:22.4KW,44.8KW,33.6KW*2,44.8KW*2 | |||||
| Standby loss | ≤3W | |||||
| Maximum conversion efficiency | >95% | |||||
| Working Mode | Battery First/AC First/Saving Energy Mode | |||||
| Transfer Time | ≤4ms | |||||
| Display | LCD | |||||
| Thermal method | Cooling fan in intelligent control | |||||
| Communication | RS232/RS485/APP/SNMP/GSM (Optional) | |||||
| Environment | Operating temperature | -10℃~40℃ | ||||
| Storage temperature | -15℃~60℃ | |||||
| Noise | 2000m(More than derating) | |||||
| Elevation | ≤65dB | |||||
| Humidity | 0%~95% ,No condensation | |||||
| Warranty | 3 years | |||||
| Note: All specifications are subject to change without prior notice | ||||||

solar inverter

HDSX 3 phase hybrid inverter installation case
Product model:
HDSX series 3 phase hybrid inverter 30KVA/40KVA/50KVA/60KVA/80KVA DC192V/384V invert to AC380V/400V, with 50A-200A PWM charge controller
Certificate::
CE、TLC、IEC
Application:
Xindun 3 phase hybrid inverter can be used in water pump, bench drill, high-power three-phase industrial motorand with total power not exceeding 24kw, 32kw, 40kw, 48kw or 64kw.
◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
◆ Built-in pwm charge controller.



HDSX 3 phase hybrid inverter installation case
◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
◆ Built-in pwm charge controller.



HDSX 3 phase hybrid inverter installation case
$1
In Stock
已选1
Buy Quantity