Parameter
功率◆ Pure sine wave output.
◇ Wide AC voltage input range, AVR output.
◆ Adopt traditional EI transformer , stable performance.
◇ LCD/LED&LCD real-time display, concise and straightforward.
◆ Working modes: AC first or battery first optional, intelligent charging.
◇ RS232 communication port optional.
Specification | |||||
Model NB-T | 12396/192 | 153192/240 | 203192/240 | 253240 | |
Rated Power | 12KW | 15KW | 20KW | 25KW | |
Peak Power(20ms) | 36KW | 45KW | 60KW | 75KW | |
Start Motor | 7HP | 10HP | 10HP | 15HP | |
Battery Voltage | 96/192VDC | 192/240VDC | 192/240VDC | 240VDC | |
Size(L*W*Hmm) | 600*300*800 | ||||
Packing Size(L*W*Hmm) | 665*365*830 | ||||
N.W.(kg) | 102 | 108 | 113 | 119 | |
G.W.(kg)(Carton Packing) | 115 | 121 | 130 | 136 | |
Installation Method | Tower | ||||
Parameter | |||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||
AC Input Voltage Range | 98VAC~125VAC / 195VAC~250VAC | ||||
AC Input Frequency Range | 45Hz~64Hz | ||||
Max AC charging current | 15A MAX(Depending on the model) | ||||
AC charging voltage | LEAD battery:Charge Voltage :14V; Float Voltage:13.8V(Single battery voltage) | ||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||
Output | Efficiency(Battery Mode) | ≥85% | |||
Output Voltage(Battery Mode) | 110VAC±2% / 220VAC±2%(Battery Mode) | ||||
Output Frequency(Battery Mode) | 50Hz±0.5 or 60Hz±0.5 | ||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||
Efficiency(AC Mode) | >99% | ||||
Output Voltage(AC Mode) | 110VAC±10% / 220VAC±10% | ||||
Output Frequency(AC Mode) | Tracking Automatically | ||||
Output waveform distortion(Battery Mode) | ≤3%(Linear load) | ||||
No load loss(Battery Mode) | ≤1% rated power | ||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||
No load loss(Energy saving Mode) | ≤10W | ||||
Battery Type | Customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements | |||
Protection | Battery undervoltage alarm | 11V(Single battery voltage) | |||
Battery undervoltage protection | 10.5V(Single battery voltage) | ||||
Battery overvoltage alarm | 15V(Single battery voltage) | ||||
Battery overvoltage protection | 17V(Single battery voltage) | ||||
Battery overvoltage recovery voltage | 14.5V(Single battery voltage) | ||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||
Output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||
Temperature protection | >90°C(Shut down output) | ||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||
Inside Solar controller | Charging Mode | PWM | |||
Charging current | 96V/192V/240V System: 50A,100A | ||||
PV Input Voltage Range | 96V System:120V-176V; 192V System:240V-352V; 240V System:300V-440V | ||||
Max PV Input Voltage(At 25℃) | 96V System:200V; 192V System:400V; 240V System:500V | ||||
PV Array Maximum Power | 96V System:5.6KW,11.2KW;192V System:11.2KW,22.4KW;240V System:14KW,28KW | ||||
Standby loss | ≤3W | ||||
Maximum conversion efficiency | >95% | ||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||
Transfer Time | ≤4ms | ||||
Display | LCD | ||||
Thermal method | Cooling fan in intelligent control | ||||
Communication | RS232(Optional) | ||||
Environment | Operating temperature | -10℃~40℃ | |||
Storage temperature | -15℃~60℃ | ||||
Noise | ≤55dB | ||||
Elevation | 2000m(More than derating) | ||||
Humidity | 0%~95% ,No condensation | ||||
Warranty | 3 years | ||||
Note: All specifications are subject to change without prior notice |
Xindun solar Inverter
NB-T Hybrid Inverter installation case
Product model:
NB-T series hybrid inverter off grid 12kw 96v/192v, 15kw 192v/240v, 20kw 192v/240v, 25kw 240v to 110v/220v, built-in 50a-100a pwm controller
Certificate::
CE、IEC
Application: Xindun hybrid inverter is suitable for off-grid solar power system independent of power grid. It can be used in industrial electric equipment, such as industrial pumps, drilling pump, electric drill and some transmission equipment with total load power not exceeding rated power of the inverter.
◆ Pure sine wave output.
◇ Wide AC voltage input range, AVR output.
◆ Adopt traditional EI transformer , stable performance.
◇ LCD/LED&LCD real-time display, concise and straightforward.
◆ Working modes: AC first or battery first optional, intelligent charging.
◇ RS232 communication port optional.
NB-T Hybrid inverter installation case
◆ Pure sine wave output.
◇ Wide AC voltage input range, AVR output.
◆ Adopt traditional EI transformer , stable performance.
◇ LCD/LED&LCD real-time display, concise and straightforward.
◆ Working modes: AC first or battery first optional, intelligent charging.
◇ RS232 communication port optional.
NB-T Hybrid inverter installation case
$0
In Stock
已选0
Buy Quantity