Parameter
功率◇ Pure sine wave output;
◆ The adjustable AC charging current 0-30A AVR output;
◇ Low frequency toroidal transformer increase efficiency;
◆ The special DCP chip is designed to run smoothly and at high speed.
◇ The query function of fault code is added to facilitate real-time monitoring operation.
◆ Support diesel or gasoline generators to adapt to any harsh electric environment;
◇ RS232 or RS485 communication port is optional.
| Specification | ||||
| Model LW-T | 40224/48 | 50248 | 60248 | |
| Rated Power | 4000W | 5000W | 6000W | |
| Peak Power(20ms) | 12000W | 15000W | 18000W | |
| Start Motor | 3HP | 4HP | 4HP | |
| Battery Voltage | 24/48VDC | 48VDC | ||
| Size(L*W*Hmm) | 570*261*199 | |||
| Packing Size(L*W*Hmm) | 625*320*295 | |||
| N.W.(kg) | 22.5 | 24 | 26 | |
| G.W.(kg)(Carton Packing) | 24 | 26 | 28 | |
| Installation Method | Wall-Mounted | |||
| Parameter | ||||
| Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | ||
| AC Input Voltage Range | 85VAC~138VAC /89VAC~144VAC / 93VAC~150VAC / 170VAC~275VAC / 178VAC~288VAC /186VAC~300VAC | |||
| AC Input Frequency Range | 45Hz~65Hz | |||
| Max AC charging current | 30A/25A | 30A | 30A | |
| AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||
| Output | Efficiency(Battery Mode) | ≥85% | ||
| Output Voltage(Battery Mode) | 110VAC±2% / 115VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | |||
| Output Frequency(Battery Mode) | 50/60Hz±1% | |||
| Output Wave(Battery Mode) | Pure Sine Wave | |||
| Efficiency(AC Mode) | >99% | |||
| Output Voltage(AC Mode) | 110VAC±10% / 115VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% | |||
| Output Frequency(AC Mode) | Tracking Automatically | |||
| Output waveform distortion (Battery Mode) | ≤3%(Linear load) | |||
| No load loss(Battery Mode) | ≤0.8% rated power | |||
| No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | |||
| No load loss(Energy saving Mode) | ≤10W | |||
| Battery Type (selectable) | LEAD | Charge Voltage:14V; Float Voltage:13.8V(Single battery voltage) | ||
| OP-LE | Charge Voltage:14.2V; Float Voltage:13.8V(Single battery voltage) | |||
| LITHIUM | Charge Voltage:13V(Single battery voltage) | |||
| Customize battery | Charge and discharge parameters of different types of batteries can be customized according to user requirements | |||
| Protection | Battery undervoltage alarm | 11V(Single battery voltage),LITHIUM 9.5V(Single battery voltage) | ||
| Battery undervoltage protection | 10.5V(Single battery voltage),LITHIUM 9V(Single battery voltage) | |||
| Battery overvoltage alarm | 15V(Single battery voltage),LITHIUM 14V(Single battery voltage) | |||
| Battery overvoltage protection | 17V(Single battery voltage),LITHIUM 15V(Single battery voltage) | |||
| Battery overvoltage recovery voltage | 14.5V(Single battery voltage),LITHIUM 13.5V(Single battery voltage) | |||
| Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
| Output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
| Temperature protection | >90°C(Shut down output) | |||
| Alarm | A | Normal working condition, buzzer has no alarm sound | ||
| B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||
| C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||
| Inside Solar controller | Charging Mode | PWM | ||
| Charging current | 10A,20A,30A,40A,50A,60A | |||
| PV Input Voltage Range | 24V System:30V-44V;48V System:60V-88V | |||
| Max PV Input Voltage (At 25℃) | 24V System:50V;48V System:100V | |||
| PV Array Maximum Power | 24V System:280W,560W,840W,1120W,1400W,1680W; 48V System:560W,1120W,1680W,2240W,2800W,3360W | |||
| Standby loss | ≤3W | |||
| Maximum conversion efficiency | >95% | |||
| Working Mode | Battery First/AC First/Saving Energy Mode | |||
| Transfer Time | ≤4ms | |||
| Display | LCD | |||
| Thermal method | Cooling fan in intelligent control | |||
| Communication | RS232/RS485(Optional) | |||
| Environment | Operating temperature | -10℃~40℃ | ||
| Storage temperature | -15℃~60℃ | |||
| Noise | ≤55dB | |||
| Elevation | 2000m(More than derating) | |||
| Humidity | 0%~95% ,No condensation | |||
| Warranty | 3 years | |||
| Note: All specifications are subject to change without prior notice | ||||
4000w 5000w 6000w pure sine wave 120v inverter

inverter
to be added...
Product model:
LW-T series controller inverter 4kw 24v/48v, 5kw/6kw 48v convert to 110v/220v, built in 10a-60a pwm controller
Certificate::
CE、IEC
Application: Xindun controller inverter can be used in air conditioner, induction cooker, rice cooker, water pump, electric drill and other electrical appliances with total power not exceeding 4kw, 5kw or 6kw.
◇ Pure sine wave output;
◆ The adjustable AC charging current 0-30A AVR output;
◇ Low frequency toroidal transformer increase efficiency;
◆ The special DCP chip is designed to run smoothly and at high speed.
◇ The query function of fault code is added to facilitate real-time monitoring operation.
◆ Support diesel or gasoline generators to adapt to any harsh electric environment;
◇ RS232 or RS485 communication port is optional.


to be added...
◇ Pure sine wave output;
◆ The adjustable AC charging current 0-30A AVR output;
◇ Low frequency toroidal transformer increase efficiency;
◆ The special DCP chip is designed to run smoothly and at high speed.
◇ The query function of fault code is added to facilitate real-time monitoring operation.
◆ Support diesel or gasoline generators to adapt to any harsh electric environment;
◇ RS232 or RS485 communication port is optional.


to be added...
$0
In Stock
已选0
Buy Quantity