Specification | |||||||||
Model: HDSX | 4KVA | 6KVA | 7KVA | 8KVA | 10KVA | 15KVA | 20KVA | 25KVA | |
Rated Power | 3.2KW | 4.8KW | 5.6KW | 6.4KW | 8KW | 12KW | 16KW | 20KW | |
Battery Voltage | 48/96/192VDC | 96/192/384VDC | |||||||
Size(L*W*Hmm) | 565*300*775 | 725*365*1010 | |||||||
Packing Size(L*W*Hmm) | 625*360*895 | 785*425*1135 | |||||||
N.W.(kg) | 58 | 73 | 75 | 80 | 99 | 110 | 145 | 164 | |
G.W.(kg) (Wooden Packing) | 71 | 86 | 88 | 93 | 126 | 127 | 162 | 181 | |
Specification | |||||||||
Model: HDSX | 30KVA | 40KVA | 50KVA | 60KVA | 80KVA | 100KVA | 125KVA | 150KVA | |
Rated Power | 24KW | 32KW | 40KW | 48KW | 64KW | 80KW | 100KW | 120KW | |
Battery Voltage | 192/384VDC | 384VDC | |||||||
Size(L*W*Hmm) | 715*575*1275 | 925*760*1450 | |||||||
Packing Size(L*W*Hmm) | 775*635*1400 | 990*825*1590 | |||||||
N.W.(kg) | 174 | 202 | 297 | 326 | 398 | 850 | 900 | 1120 | |
G.W.(kg) (Wooden Packing) | 198 | 226 | 321 | 350 | 422 | 895 | 945 | 1165 | |
Parameter | |||||||||
Input | AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||||||
AC Input Frequency Range | 45Hz-65Hz | ||||||||
Phase | 3/N/PE | ||||||||
Output | Efficiency | ≥85% | |||||||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | ||||||||
Output Wave(Battery Mode) | Pure Sine wave | ||||||||
THD | liner load≤3% | ||||||||
AC Output Voltage Range | Conforming to AC input | ||||||||
AC Output Frequency Range | Conforming to AC input | ||||||||
Phase | 3/N/PE | ||||||||
Battery | DC input voltage range | 10.5-17V DC/Single battery | |||||||
Battery low voltage alarm | 11V/Single battery | ||||||||
Battery low voltage protection | 10.5V DC/Single battery | ||||||||
Battery high voltage alarm | 15V/Single battery | ||||||||
Battery high voltage protection | 17VDC/Single battery | ||||||||
Battery Type | U0: Gel U.S.A / U1: A.G.M.1 /U2: A.G.M.2 / U3: Sealed lead Acid / U4: Gel European / U5: Open lead Acid / U6: Calcuim(open) / U7: Sulphation cycle | ||||||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||||||
AC Charging current(selectable) | 0~45A | ||||||||
Transfer Time | ≤4ms | ||||||||
Display | LCD | ||||||||
Thermal method | Forced air cooling | ||||||||
Protection | Over-load / Over-discharge / Short circuit / High and low temperayure | ||||||||
Communication | RS232/RS485/APP/SNMP/GSM (Optional) | ||||||||
Environment | Temperature | -10℃~40℃ | |||||||
Height | 2000m(Less load when height over) | ||||||||
Noise | ≤65dB | ||||||||
Humidity | 0%~95%(No condense) | ||||||||
Note:All specifications are subject to charge without prior notice |
solar inverter
HDSX Uninterruptible Power System
Product certification:
CE、IEC
Application area
Widely used in finance, communications, insurance, transportation, taxation, telecommunications, power, government agencies, building lighting, centralized server room, network management center and computer center, industrial automation equipment, working conditions enterprises and other industries.
◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
HDSX Uninterruptible Power System
◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ AC charge current 0-45A adjustable.
◆ 100% imbalance loading design, 3 times peak power.
◇ Setting different working modes based on variable usage requirements.
◆ DC first/AC first optional.
◇ Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
HDSX Uninterruptible Power System
¥0
In Stock
已选0
Buy Quantity